Product Description
Compression Refrigeration Unit
Specification of Compression Refrigeration Unit
- Investigation of a refrigeration system with different expansion elements
- Refrigeration circuit consisting of a hermetic compressor, condenser, evaporator and expansion element
- Transparent finned tube heat exchangers as condenser and evaporator to observe the phase transitions of the refrigerant
- Expansion valve and capillary tubes of different lengths as expansion elements
- Receiver for underfilling/overfilling the system with refrigerant
- Sensors record pressure and temperature
- Compressor equipped with two pressure switches
Technical Data
Compressor
- Power consumption: 213W at 7,2°/32°C
- Refrigeration capacity: 372W at 7,2/32°C
- Condenser and evaporator with fan
- Max. Volumetric air flow rate condenser: 300m³/h
- Max. Volumetric air flow rate evaporator: 180m³/h
- Capillary tubes: 1,5m, 3m, 6m
- Receiver for refrigerant: 1,3L
Measuring ranges
- Pressure: -1...9bar / -1...24bar
- Temperature: 4x -40...150°c, 1x -100...100°c
- Flow rate: 2...18m³/h
- Electric power consumption: 0...1000W