Send Inquiry
Send SMS
Temperature Measurement Methods and Calibration Unit

Temperature Measurement Methods and Calibration Unit

50000.00 - 500000.00 INR/Pack

Product Details:

X

Temperature Measurement Methods and Calibration Unit Price And Quantity

  • 50000.00 - 500000.00 INR/Pack
  • 1 Pack

Temperature Measurement Methods and Calibration Unit Trade Information

  • 10 Pack Per Month
  • 10-30 Days
  • Export Worthy
  • ISO

Product Description

Description of DIDAC Temperature Measurement Methods and Calibration Unit

The measurement of temperature is fundamental to almost every branch of engineering and science. The Temperature Measurement Methods and Calibration Unit enables students to investigate the many different methods of measuring temperature and to determine the advantages and disadvantages of the various sensor and indicator types. Up to nine different methods of Temperature Measurement Methods and Calibration Unit are included and students undertake detailed experiments to compare not only accuracy but also the way in which the instruments work. The operation of platinum resistance temperature sensors and their importance in the International Temperature Scale are investigated.

Experimental Capabilities Temperature Measurement Methods and Calibration Unit:

  • The use of liquid in glass thermometers for measurement of fixed scale points.
  • The use of vapour pressure for temperature measurement.
  • The use of bi-metallic expansion devices for temperature measurement.
  • The Peltier and Seebeck thermo-electric effects.
  • Investigation of junction voltage from different thermocouple types.
  • The use of ice point reference with a thermocouple.
  • The law of intermediate metals and intermediate temperatures associated with thermocouples.
  • Voltage calibration of different thermocouple types using a water-ice reference.
  • The effect of lead resistance and voltmeter meter impedance on thermocouple measurements.
  • Use of a direct reading, internally compensated thermocouple indicator.
  • Connection of thermocouples in series for signal amplification and parallel for averaging of measured temperatures.
  • Investigation of the response rate of various thermocouples and sensors.
  • Investigation of the platinum resistance sensor, its resistance change with temperature and the reference PRT equation
  • The use of a direct reading PRT indicator device.
  • Investigation of the resistance change of a negative temperature coefficient thermistor sensor with temperature.
  • The use of a direct reading thermistor indicator device.
  • Calibration of all of the supplied sensors with reference to an accurate platinum resistance thermometer

Specification of Temperature Measurement Methods and Calibration Unit:

  • The unit is supplied with a detailed experimental operating and maintenance manual giving example experimental results and sample calculations.
  • Accessories and spares for two years normal operation together with a full two year warranty are also included as standard.
  • A bench top control console with accurate platinum resistance thermometer thermistor indicator, thermocouple indicator with selector switches and an accurate millivolt meter.
  • All electronic indicators include re-transmission signals for use by user supplied chart recorders, data acquisition systems or an optional 35 channel data acquisition system with menu driven software which can be supplied by DIDAC
Enter Buying Requirement Details
Email Id
Mobile number

Other Products in 'Heat Transfer Lab Equipments' category



trade india member
DIDAC INTERNATIONAL All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.