Product Description
Heat Pump for Cooling And Heating Operation
Specification of Heat Pump For Cooling And Heating Operation
- Air-to-water heat pump for cooling or heating operation
- Different operating modes selectable via solenoid valves
- Refrigeration circuit with compressor, condenser (heat exchanger with fan), 2 evaporators with fan (refrigeration and freezing stage)
- Glycol-water circuit with tank, pump and coaxial coil heat exchanger
- Coaxial coil heat exchanger and heat exchanger with fan can both be used as condenser or evaporator in the refrigeration circuit
- 1 thermostatic expansion valve each for all heat exchangers and evaporators
- 1 additional evaporation pressure controller and 1 capillary tube for the refrigeration stage evaporator
- Displays for temperature, pressure, flow rate and power consumption of the compressor.
Technical Data of Heat Pump For Cooling And Heating Operation
Compressor
- Refrigeration capacity: 934W at -6,7/55°C
- Power consumption: 620W at -6,7/55°C
- Heat exchanger with fan
- Transfer area: 1,25m², volumetric air flow
- Rate: 650m³/h, capacity: 1148W at DT=15K
- Evaporators with fan
- Refrigeration stage
- Transfer area: 1,21m², volumetric air flow
- Rate: 80m³/h, capacity: 140w (tl1=5°c, dt1=10k)
- Freezing stage
- Transfer area: 3,62m², volumetric air flow
- Rate: 125m³/h, capacity: 330W (tL1=5°C, DT1=10K)
- Coaxial coil heat exchanger
- Capacity: 1,6kW at 0°C; DT=9K
Measuring ranges
- Temperature: 11x -50...150°c
- Pressure: 2x -1...15bar, 1x -1...24bar
- Flow rate (refrigerant): 1x 4...40l/h
- Flow rate (glycol-water): 1x 2,5...65g/s
- Power: 0...1150W