Product Description
Electrical Installation in Refrigeration Systems
Specification of Electrical Installation in Refrigeration Systems
- Experimental unit from the practical series for the training of mechatronics engineers for refrigeration
- Design and investigation of circuits with electrical components from refrigeration
- Electrical components mounted clearly visible and connected on terminal blocks
- 1 set of cables with wire end ferrules for wiring electrical components on terminal blocks
- 3 pressure switches, 2 thermostats, 1 solenoid valve, 1 timer, 4 circuit breakers, 5 contactors, 3 relays, 2 capacitors
- 5 lamps to simulate consumers
Technical Data
3 pressure switches
- High pressure: 8...32bar
- Low pressure: -0,9...7bar
- Differential pressure: 0,3...4,5bar
- 2 thermostats: -5...20°C
- 1 timer
- 2 switchable outputs
- Switching time: 1...60min
4 circuit breakers
- Bimetallic circuit breaker
- Thermistor circuit breaker
- Circuit breaker with start-up current limiter
- Adjustable protection relay
- 5 contactors
- 2x: 3 NO, 1 NC
- 3x: 4 NO
- 3 relays
- Electromagnetic start-up relay
- Ptc start-up relay
- Time relay