All 3 CRP dynamometer types have separate driveshafts for the forward and rear dynamometer to facilitate the connection of two motors. It is therefore possible to control the speed of the forward and the rear dynamometer independently from each other. Alternatively, the two driveshafts can be connected through a gearbox normally with a transmission ratio of1:1 so that it is possible to drive both the forward and the rear dynamometerat the same speed in opposite directions, from one motor..
Specification of CRP Dynamometers
- Rated torque: ± 7Nm
- Rated thrust: ±250 N
- Maximum speed (provided that suitable drive equipment is available): 1800 rpm
- Current supply for the measuring system (constant voltage): d.c. or a.c.
- Sensitivity at rated torque and thrust, output voltage/supply voltage, approximately: 1.5 mV/V
- Torque measurement:
- Input bridge resistance, approximately: 274©
- Output bridge resistance, approximately: 240©
- Recommended supply voltage: up to 8V
- Max. supply voltage: 20V
- Thrust measurement:
- Input bridge resistance, approximately: 133©
- Output bridge resistance, approximately: 120©
- Recommended supply voltage: up to 6V
- Max. supply voltage: 10V
- Net weight without calibration device,approximately: 17 kg
- Rated torque: ±3 Nm
- Rated thrust: ±30 N
- Maximum speed (provided that suitable drive equipmentis available): 1800 rpm
- Current supply for the measuring system (constant voltage): d.c. or a.c.
- Sensitivity at rated torque and thrust, output voltage/supply voltage, approximately: 1.5 mV/V
- Torque measurement:
- Input bridge resistance, approximately : 274©
- Output bridge resistance, approximately: 240©
- Recommended supply voltage: up to 8V
- Max. supply voltage: 20V
- Input bridge resistance, approximately: 133©
- Output bridge resistance, approximately: 120©
- Recommended supply voltage: up to 6V
- Max. supply voltage: 10V
- Net weight without calibration device,approximately: 17 kg
- Rated torque: ±24Nm
- Rated thrust: ±700 N
- Maximum speed (provided that suitable drive equipment is available): 1800 rpm
- Current supply for the measuring system (constant voltage): d.c. or a.c.
- Sensitivity at rated torque and thrust, output voltage/supply voltage, approximately: 2 mV/V
- Torque measurement:
- Input bridge resistance, approximately : 259©
- Output bridge resistance, approximately: 240©
- Recommended supply voltage: up to 8V
- Max. supply voltage: 20V
- Input bridge resistance, approximately: 378©
- Output bridge resistance, approximately: 350©
- Recommended supply voltage: up to 8V
- Max. supply voltage: 20V
- Net weight without calibration device,approximately: 21 kg
- Inclusive stern tube, however without gearbox (1 kgforce = 980665 N)