Product Description
Comparison Of Different Heating Unit
Specification of Comparison Of Different Heating Unit
- Together with hot water generator: setup of a complete domestic heating system with 2 independent heating circuits
- Heating circuit (a) with floor heating, circulating pump, heating controller, and 3-way mixing valve
- Heating circuit (b) with forced convector with fan, 2 radiators and circulating pump
- 1 radiator with thermostatic valve and 1 radiator with 1-pipe radiator valve
- Room temperature controller for fan of forced convector
- Measurement of flow rate and pressure
- 8 measuring points for differential pressure and
- Hot water connections with quick-release couplings
Technical Data
Floor heating, Cu pipes
- Length: 7500mm
- Diameter pipe: 14mm
- Wall thickness: 0,8mm
- Filling volume: 1,2L/m
Radiator, Steel
- Heating capacity: 492W at feed flow 70°C,
- Return flow 55°C and ambient temperature 20°C
Air heater
- Heating capacity: 7,14...9,32kw at feed flow 90°c,
- Return flow 70°c and inlet temperature 15°c
- Max. flow rate: 1260m³/h
Pump
- Max. Power consumption: 60w
- Max. Flow rate: 3600l/h
- Max. head: 4m
- Thermostatic valve: 5...26°C
Measuring Ranges
- Pressure: 2x 0...1,6bar
- Differential pressure: 1x 0...0,25bar
- Flow rate: 1x 15...160l/h, 1x 100...1000l/h,
- 1x 20...250l/h