Product Description
Capacity Control And Faults In Refrigeration Systems
- Investigation of a refrigeration system with refrigeration and freezing chambers
- Refrigeration circuit with compressor, condenser, capacity controller, start-up controller, combined pressure switch and 2 evaporators in insulated chambers
- Each chamber with solenoid valve, thermostat, thermostatic expansion valve, fan and heat exchanger for refrigerant supercooling
- Refrigeration chamber with evaporation pressure controller
- Freezing chamber with electric defrost heater and hot gas defrosting
- Separate or parallel operation of the chambers via solenoid valves
- Simulation of 12 faults
- Touch panel pc for fault activation, data acquisition, evaluation and representation in the
- Log p-h diagram
- Refrigerant R404a
Technical Data
Compressor
Refrigeration capacity: 2440W at -10/30°C
Condenser With Fan
Volumetric air flow rate: 570m³/h
Evaporator Transfer Areas
- Refrigeration chamber: 1,12m²
- Freezing chamber: 1,88m²
- Electric defrost heater: approx. 125W
- Capacity controller: 0,2...6bar
- Start-up controller: 0,2...6bar
- Thermostat: 2x -25...15°C
- Evaporation pressure controller: 0...5,5bar
Measuring Ranges
- Temperature: 6x -50...50°c; 5x 0...100°c
- Pressure: 3x -1...12,5bar; 2x -1...24bar
- Flow rate: 2x 1.5...22,5l/h
- Compressor power consumption: 0...5kW